☆  Pulse Oximeters
☆  Infant Incubator
☆  Infant Radiant Warmer
☆  Transcutaneous Jaundice Detector
☆  SPO2 Sensors
☆  Ophthalmology Ultrasound
☆  Digital Thermometer
☆  Blood Pressure Meter
☆  Blood Glucose Meter
☆  Patient Monitor
☆  ETCO2 Module
☆  NIBP Module
☆  ECG Cables
☆  Temperatures sensors
☆  Infusion/Syringe Pumps
☆  Ophthalmic Equipments
☆  Nebulizer
☆  Module Accessories
☆  Defibrillator
☆  SPO2 module
☆  Video Laryngoscope
  Products Show  

HX-801D Infusion Pump

HX-801D Infusion Pump

I. FEATURES

n         Complies with IEC 60601, higher security designation with dual CPUs;

n         CE certified;

n         High brightness LCD display and user-friendly operation interface;

n         Easy switch among d/min, mL/h and volume/time unit;

n         Available for Bolus mode;

n         Anti-reverse function on motor to prevent upstream;

n         Self-check when start up and in process;

n         Top pressure sensor for preventing underflow;

n         Pressure and air-in-line detection devices both with 8 sensitivities setting, dynamically display pressure value;

n         IV set management function: Up to 20 IV sets can be added, stored and deleted in memory, convenient for operation after calibration;

n         Adjustable 8 volume levels of alarm for convenient operation in different environments;

n         Multi-Languages: English, French, Turkish, Polish, Spanish, Russian, Chinese.

 

II. SPECIFICATIONS

Specification

Infusion Mode:

Volumetric

Pumping Mechanism:

Peristaltic finger pump

IV Sets:

Standard IV sets of 10, 15, 20 and 60d/mL

Optional Rate Unit:

d/min, mL/h and volume/time

Flow Rate Range:

1.01200 m L/h

Increment:

0.1mL/ h

Volume Limit:

19999 mL

Volume Infused Display:

09999 mL & >9999 mL

Flow Rate Accuracy:

≤ ± 5% (after calibration)

Purge Rate:

600 mL/h

KVO Rate:

1 mL/h

Bolus Mode:

Bolus rate adjustable

Occlusion Pressure:

Pressure detection device with 8 sensitivities setting,

40 ~ 140KPa.

Air-in-line Detection: 

Air-in-line detection device with 8 sensitivities setting,

50 ~ 1000μL.

IV Set Management

&

Flow Rate Calibration:

Up to 20 IV sets of customers' brand can be added, stored and deleted in memory,

convenient for operation after calibration

Display:

Blue LCD with high brightness

Power Source:

AC: 100V ~ 240V, 50Hz/60Hz, ≤ 25VA

Battery:

Rechargeable Ni-MH battery: DC12V,2000mAh,

life: ≥ 4 hours at 25mL/h

Classification:

Class, CF, IPX4

Dimensions and N.W.: 

150mm x 150mm x 235mm; 2.3kg

Warranty:

Two years

Accessory

Power Cord

1 pc

Operator Manual:

1 pc

Packing

Inner box:

230*175*285mm

Carton:

480*360*300 (4 sets/CTN)